DR-120-12 din rail power supply 12V 10A SMPS
120W Single Output Industrial DIN Rail Power Supply DR-120 series
Features:
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switch frequency at 55KHz
2 years warranty












Contact us for more details.
120W Single Output Industrial DIN Rail Power Supply DR-120 series
Features:
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switch frequency at 55KHz
2 years warranty
| SPECIFICATIONS | |||||
| OUTPUT | |||||
| Model | DR-120-12 | DR-120-24 | DR-120-48 | ||
| DC Voltage | 12V | 24V | 48V | ||
| Rated Current | 10A | 5A | 2.5A | ||
| Current Range | 0-10A | 0-5A | 0-2.5A | ||
| Rated Power | 120W | 120W | 120W | ||
| Ripple & Noise | 80mVp-p | 80mVp-p | 100mVp-p | ||
| Voltage Adj. Range | 12-14V | 24-28V | 48-53V | ||
| Voltage Tolerance | ±2% | ±1% | ±1% | ||
| Line regulation | ±0.5% | ±0.5% | ±0.5% | ||
| Load regulation | ±1% | ±1% | ±1% | ||
| Setup, Rise Time | 500ms,70ms/230VAC 500ms,70ms/115VAC at full load | ||||
| Hold Up Time | 36ms/230VAC 32ms/115VAC at full load | ||||
| INPUT | |||||
| Voltage Range | 88~132VAC/176~264VAC selected by switch 47~63Hz; 248~370VDC | ||||
| AC Current | 2.6A/115VAC 1.6A/230VAC | ||||
| Efficiency | 80% | 84% | 85% | ||
| Inrush Current | Cold start 20A/115V 40A/230V | ||||
| Leakage Current | <3.5mA/240VAC | ||||
| PROTECTION | |||||
| Over Load | 105%~150% rated output power | ||||
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||
| Over Voltage | 15-16.5V | 29-33V | 58-65V | ||
| Protection type: Shut down o/p voltage, re-power on to recover | |||||
| Over Temp. | 85ºC±5ºC(TSW1) | 90ºC±5ºC(TSW1) | 90ºC±5ºC(TSW1) | ||
| Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | |||||
| ENVIRONMENT | |||||
| Working Temp., Humidity | -10ºC~+60ºC; 20%~90% RH non-condensing | ||||
| Storage Temp., Humidity | -20ºC~+85ºC; 10%~95%RH | ||||
| Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | ||||
| SAFETY | |||||
| Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC/25ºC/70%RH | ||||
| STANDARD | |||||
| Safety Standard | Design refer to UL508,UL60950-1,TUV EN60950-1 | ||||
| EMC Standard | Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2(EN50082-2), heavy industry level, criteria A | ||||
| OTHERS | |||||
| Dimension | 65.5*125.2*100mm(L*W*H) | ||||
| Weight | 0.79Kg | ||||
| Packing | 20pcs/carton/16.5kg/1.29CUFT | ||||
| NOTE | |||||
| 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |||||












Contact us for more details.