IVY Antimagnetic Timing Switch Relay with UL for Smart Meters

Basic DataDimension(mm)79.5×54×26Weight ( g )≈208gContact Arrangement2A/2BContact MaterialAgSnO2Ambient Temperature-45~+85ºCVibration10~50Hz,0.75mmShock1000m/s²,(100g)Specification DataNominal Voltage16VDCPower Consumption<1.5WOperating Voltage16VMax. Motor Voltage48VMax. Switching Current200ASurge

Featured Products

IVY Anti-Magnetic Timer Switch Relay with UL for Smart MeterIVY Anti-Magnetic Timer Switch Relay with UL for Smart Meter
IVY Anti-Magnetic Timer Switch Relay with UL for Smart Meter
Basic DataDimension(mm)79.5×54×26
Weight ( g )208g
Contact Arrangement2A/2B
Contact MaterialAgSnO2
Ambient Temperature-45~+85ºC
Vibration10~50Hz,0.75mm
Shock1000m/s²,(100g)
Specification DataNominal Voltage16VDC
Power Consumption<1.5W
Operating Voltage16V
Max. Motor Voltage48V
Max. Switching Current200A
Surge Current3000A/10ms
Motor Resistance(R±20%)55Ω
Contact Voltage<60mV
Contact Resistance<0.6
Dielectric StrengthMotor to Contact>4000VAC   1min
Across Open Contact>2000VAC   1min
Electrical Life>10000cycles
Mechanical Life>100000cycles
Pulse Time100ms~150ms
Picking-up Time<65ms
Release Time<65ms
Insulation Resistance>1000MΩ(500VDC)


IVY Anti-Magnetic Timer Switch Relay with UL for Smart Meter
IVY Anti-Magnetic Timer Switch Relay with UL for Smart MeterIVY Anti-Magnetic Timer Switch Relay with UL for Smart Meter
IVY Anti-Magnetic Timer Switch Relay with UL for Smart Meter


IVY Anti-Magnetic Timer Switch Relay with UL for Smart MeterIVY Anti-Magnetic Timer Switch Relay with UL for Smart MeterIVY Anti-Magnetic Timer Switch Relay with UL for Smart Meter
          Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours