Sul181h series timer relay (timer, programmable timer)

Voltage AC24V-220V 50Hz DC24V-110VContact Timed SPOT Inst. SPOTOperation On-delay with inst. ContactTiming range 1S 2S 3S 6S 12S 30S 60S 2M 3M 5M 6M 12M 30M 60M 3H 6H 12H 24HVoltage AC24V-220V 50Hz DC24V-110VContact H3Y-2, ST6P: Timed 2PDT H3Y-4, ST6P-4: Timed 4PDTOperation H3Y-4, ST6P-2 Time-limit operation/self-resttingTiming

Featured Products

Voltage AC24V-220V 50Hz DC24V-110V
Contact Timed SPOT Inst. SPOT
Operation On-delay with inst. Contact
Timing range 1S 2S 3S 6S 12S 30S 60S 2M 3M 5M 6M 12M 30M 60M 3H 6H 12H 24H

Voltage AC24V-220V 50Hz DC24V-110V
Contact H3Y-2, ST6P: Timed 2PDT H3Y-4, ST6P-4: Timed 4PDT
Operation H3Y-4, ST6P-2 Time-limit operation/self-restting
Timing range 0.5S 1S 5S 10S 30S 60S 120S 180S 10M 30M 60M 3H 12H 24H

Voltage AC24V-240V 5OHZ DC12V-110V
Contact H3BA-8: Timed 2PDT H3BA-8H: Timed SPDT, Inst. SPDT
Operation H3BA-8: On-delay H3BA-8H: On-delay with inst. Contact
Timing range 0.5S-100H

Voltage AC24V-240V 5OHZ DC12V-48V
Contact Timed 2PDT
Operation On-delay recycling work off-delay on/off-delay
Timing range 0.5S-100H

Voltage AC24V-220V 5OHZ DC24V-48V
Contact AH3-1: Timed SPDT AH3-2: Timed 2PDT AH3-3: Timed SPDT, Inst. SPDT
Operation AH3-1: Time-limit operation/self-resetting AH3-2: On-delay AH3-3: On-delay with inst. Contact
Timing range 1S 2S 3S 6S 12S 30S 60S 2M 3M 5M 6M 12M 30M 60M 3H 6H 12H 24H

Voltage AC24V-220V 5OHZ DC24V-110V
Contact AH2-Y1: Timed SPDT AH2-Y2: Timed 2PDT AH2-Y: Timed SPDT, inst. SPDT
Operation AH2-Y1: Time-limit operation/self-resetting AH2-Y2: On-delay AH2-Y: On-delay with inst. Contact
Timing range 1S 2S 3S 6S 12S 30S 60S 2M 3M 5M 6M 12M 30M 60M 3H 6H 12H 24H
1Model No: SUL181H

 

 

 
2Product name: 24 hours time switch

 

 

 
3Operating Voltage: 24~250V AC, 50Hz/60Hz

 

 

 
4Power Consumption: 0.5VA

 

 

 
5Ambient Temperature: -10~+50º C

 

 

 
6Accuracy: ≤ 2 s/day  25º C

 

 

 
7Contact Capacity:   AC 220V, 16A

 

 

 
8Full Timing Range: 24h

 

 

 
9Contact Resistance: ≤ 50mΩ

 

 

 
10Insulation Resistance: ≥ 100MΩ

 

 

 
11Coil Voltage: 110V, 230V AC

 

 

 
12Operating Temperature: -40º C~+55

 

 

 
13Minimum Setting Unit: 30 minutes

 

 

 
14Setup times: 30m/times 48times

 

 

 
15Storage Battery(Working reserve): 150 hours

 

 

 
16Life:Electrical          ≥ 10 5 Times

 

 
Mechanical    ≥ 10 7 Times

 

 

 
17Dimension: 90*54*65 mm

 

 

 
18DIN rail Mounting

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours