D-60A 60W dual output switching power supply 5V 5A, 12V 3A

D-60W Dual output switching power supplyFeatures: High efficiency, high reliability For AC power supply input global 100% full load and machine test Protection characteristics: short circuit/overload/pressure Has the boot display (light emitting diode (led) Air cooling Working frequency 54 KHz&

Featured Products

D-60W Dual output switching power supply

Features: 
High efficiency, high reliability 
For AC power supply input global 
100% full load and machine test 
Protection characteristics: short circuit/overload/pressure 
Has the boot display (light emitting diode (led) 
Air cooling 
Working frequency 54 KHz 
1 year warranty 
Size: 159 * 97 * 38 mm (L * W * H) 
 

model

D-60A

D-60B

CH1

CH2

CH1

CH2

output

Dc output voltage

5V

12V

5V

24V

Output voltage tolerance

±2%

±6%

±2%

±5%

Rated output current

4A

3A

3A

1.8A

Output current range

0.3-6A

0.2-4A

0.3-6A

0.2-2.2A

Output power

56W

58W

Ripple and the noise

75mVp-p

150mVp-p

75mVp-p

150mVp-p

Dc voltage adjustable scope

CH1: -5%,+10%

CH1: -5%,+10%

Start, rise, keep time

300ms,50ms ,80ms/230VAC 800ms,50ms,10ms/115VAC Loaded with

input

Input voltage range

85~264 VAC/ 47~63 Hz; 120~370VDC

Exchange input current

2A/115 V 1A/ 230 V

efficiency

73%

76%

Impulse current

Cold start current
30A/115VAC 60A/230VAC

Leakage current

<3.5mA/240VAC

Protection characteristics

Overload protection

105%~150%

Protection way: current limiting, automatic recovery

Overvoltage protection

115%~135%

Protection way: hiccups, auto recovery mode

environment

Working temperature, humidity

-10ºC~+60ºC;20%~90 %RH

Keep temperature, humidity

-20ºC~+85ºC;10%~95 %RH

Vibrate resistance

10 ~ 500 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis

security

Compression sex

3: KVAC between input and output input and ground:
1.5KVAC Output and to
:0.5KVAC

Insulation resistance

Between the input and output, the input and output, and ground:
100M Ohms/500VDC

Standards

Safety standards

UL1012 , UL60950 ,EN60950

EMC standard

Accord with
EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024

other

weight

0.54Kg

packaging

30pcs/16.7Kg/0.99CUFT

note

All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ºC conditions measuring income value.
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
The power to consider as a device installed in final equipment, this equipment must be to make sure it's EMC index.
Specific output current see output drop forehead curve.


D-60A 60W Dual Output Switching Power Supply 5V 5A, 12V 3A
 